High quality supplier platform for in-depth certification of national battery industry product query system.
Service Phone:4000-110-181
<
>
Favor
JFA Series Li Battery Formation,Grading, Testing Equipment
model/specification:
JFA-512/1
Scope of application:
It is specially designed and manufactured for lithium ion battery formation and classification.
purpose/function:
accuracy:
I want an inquiry View Phone Number
JiangSu JinFan Power Technology Co.,Ltd.
Jiangsu
Main products:
Lithium battery charging and discharging motor
Detailed Parameters
Detailed Instruction

Application: 

It is specially designed and manufactured for lithium ion battery formation and classification. 

Features: 

1. The complete cabinet adopts double-face structure, and it can be used to form and test 256 or 512 Nos of lithium batteries.

2. Adopt advanced independent control technology, free from impact from other channels, and no need to register. It is especially applicable for charging/discharging of lithium ion battery.

3. Use four-line method for measuring, which can maximally get rid of wiring and contact error. And testing precision is high.

4. Voltage sampling is of contactless switching mode, which guarantees long service life and high reliability.

5. Fast sampling speed, a complete patrol inspection only cost 2seconds.

6. Each set of host computer can connect with 1-100 cabinets. The software can set 100 steps and 9999 cycles. 

Functions: 

1. Sampling wire broken protection, voltage range protection, power leakage protection and other hardware protection functions.

2. Abnormal voltage protection, abnormal current protection, over-capacity protection, voltage fluctuation protection (constant voltage charge),power-down data protection and so on.

3. Easy operation can realize such functions as centrally controlling equipment, processing data and making report

4. The host computer with many battery inspection interfaces can save complete charging/ discharging data and curves of each battery; it also can sort batteries and make a statistic according to capacity, time, open circuit voltage, platform time, and internal resistance, etc. 

Technical Parameters: 

1. Power supply: AC380V±10%, 50HZ;

2. Constant current range: 0 ~ 100%FA, resolution: 1mA

    Current setting accuracy: ± (0.2% RD+0.1% FS)

    Measuring accuracy: ± (0.2% RD+0.1% FS)

3. Voltage measuring range: 0 ~ 5V, resolution: 1mV

    Battery voltage range: 2 ~ 4.35V

    Constant voltage setting range: DC 2~4.35V

    Constant voltage setting accuracy: ± (0.1%RD+0.1% FS)

    Voltage measuring accuracy:±(0.1%RD+0.1% FS)

4. Time Time range: 0~30000min/step; accuracy: ±0.1%

5. Communication mode: LAN

Specifications:
Models Channels Current(A) Voltage(V)
JFA-512/1 512 0-1 2-4.5
JFA-512/2 512 0-2 2-4.5
JFA-512/3 512 0-3 2-4.5
JFA-256/4 256 0-4 2-4.5
JFA-256/5 256 0-5 2-4.5
JFA-256/6 256 0-6 2-4.5